Please use this identifier to cite or link to this item: https://idr.l3.nitk.ac.in/jspui/handle/123456789/10798
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSrinikethan, G.
dc.contributor.authorShrihari, S.
dc.contributor.authorPradeepan, V.S.
dc.date.accessioned2020-03-31T08:23:05Z-
dc.date.available2020-03-31T08:23:05Z-
dc.date.issued2008
dc.identifier.citationJournal of Environmental Science and Engineering, 2008, Vol.50, 1, pp.75-82en_US
dc.identifier.urihttp://idr.nitk.ac.in/jspui/handle/123456789/10798-
dc.description.abstractLaboratory studies were conducted to assess the influence of media related factors such as porosity, pore size, particle size and specific surface area on the performance of upflow aerobic biofilters (ABFs). Three simple models of 8 litre capacity upflow submerged ABFs packed with support media of size 40 mm, 20 mm and 10 mm respectively were installed. The hydraulic retention time (HRT) was maintained as 12 hours. The study was carried out for a period of 90 days. The reactor performance indicated that the aerobic biofilter (ABF-3), associated with media of lowest porosity, pore size, particle size and highest specific surface area, demonstrating the highest BOD and COD removal efficiency of 93.32 % and 85.01 % respectively.en_US
dc.titleEffect of media characteristics on performance of upflow aerobic biofiltersen_US
dc.typeArticleen_US
Appears in Collections:1. Journal Articles

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.