Please use this identifier to cite or link to this item:
https://idr.l3.nitk.ac.in/jspui/handle/123456789/13589
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jayalekshmi, B.R. | |
dc.contributor.author | Jisha, S.V. | |
dc.contributor.author | Shivashankar, R. | |
dc.date.accessioned | 2020-03-31T08:48:13Z | - |
dc.date.available | 2020-03-31T08:48:13Z | - |
dc.date.issued | 2015 | |
dc.identifier.citation | International Journal of Advanced Structural Engineering, 2015, Vol.7, 2, pp.95-115 | en_US |
dc.identifier.uri | 10.1007/s40091-015-0085-6 | |
dc.identifier.uri | http://idr.nitk.ac.in/jspui/handle/123456789/13589 | - |
dc.description.abstract | Soil�structure interaction (SSI) analysis was carried out for tall reinforced concrete chimneys with piled raft foundation subjected to wind loads. To understand the significance of SSI, four types of soil were considered based on different material properties. Chimneys of different elevations and different ratios of height to base diameter of chimney were selected for the parametric study. The thickness of raft of piled raft foundation was also varied based on different ratios of outer diameter to thickness of raft. The chimneys were assumed to be located in open terrain and subjected to a maximum wind speed of 50�m/s. The along-wind and across-wind loads were computed according to IS: 4998 (Part 1)-1992 and applied along the height of the chimney. The analysis was carried out using three-dimensional finite element technique based on the direct method of SSI. The linear elastic material behaviour was assumed for the integrated chimney�foundation�soil system. The radial and tangential moments, lateral deflection and base moment of chimney were evaluated through SSI analysis and compared with the response obtained from chimney with fixed base. The base moment of chimney considerably reduces due to the effect of SSI. It is found that the variation of different responses in chimney due to the effect of SSI depends significantly on the geometrical properties of chimney and foundations. The response variation at base for a distance of 1/40th of the height of chimney should be considered for a safe design. � 2015, The Author(s). | en_US |
dc.title | Wind load analysis of tall chimneys with piled raft foundation considering the flexibility of soil | en_US |
dc.type | Article | en_US |
Appears in Collections: | 1. Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.